TroubleshooTing and sysTem TesTs
powermax
105
Service Manual 8-33
Fault
code
Description Power
LED
Fault
LED
Fault
icon
Solutions
3-20-0 Fill valve
Indicates that the Fill Valve is
not connected.
On On
• Check the associated wiring.
• Perform Test 9.
• If necessary, replace the electronic
regulator. (Kit 228687)
3-20-1 Dump valve
Indicates that the Dump Valve
is not connected.
• Check the associated wiring.
• Perform Test 9.
• If necessary, replace the electronic
regulator. (Kit 228687)
3-20-2 Valve ID The DSP does not recognize the electronic
regulator.
• Check the harness from the regulator to J6.
3-20-3 Electronic regulator is
disconnected
The electronic regulator is not
drawing current.
• Inspect the associated wiring, particularly
the 7-pin connector at J6 on the power
board.
• If necessary, replace the electronic
regulator.(Kit 228687)
Commenti su questo manuale